Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Sitemarte3.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador6qtX3pFwXQZsFDuKxG/zagiF
Repositóriosid.inpe.br/marciana/2003/08.15.15.37   (acesso restrito)
Última Atualização2006:02.16.15.55.00 (UTC) administrator
Repositório de Metadadossid.inpe.br/marciana/2003/08.15.15.38
Última Atualização dos Metadados2018:06.06.03.57.14 (UTC) administrator
Chave SecundáriaINPE-13535-PRE/8748
ISSN0257-8972
Chave de CitaçãoUedaSiOtReYaLeBe:2003:ImTrPr
TítuloImprovement of tribological properties of Ti6Al4V by nitrogen plasma immersion ion implantation
Ano2003
MêsJune
Data de Acesso19 maio 2024
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho83 KiB
2. Contextualização
Autor1 Ueda, Mário
2 Silva, M. M.
3 Otani, C.
4 Reuther, H.
5 Yatsuzuka, M.
6 Lepienski, C. M.
7 Berni, Luiz Ângelo
Grupo1 LAP-INPE-MCT-BR
Afiliação1 nst Nacl Pesquisas Espaciais, Lab Associado Plasma, BR-12201 Sao Jose Dos Campos, SP, Brazil
2 Inst Tecnol Aeronaut, Dept Engn Mecan, Sao Jose Dos Campos, Brazil
3 Inst Tecnol Aeronaut, Dept Fis, Sao Jose Dos Campos, Brazil
4 Rossendorf Inc, Inst Ion Beam Phys & Mat Res, D-01314 Dresden, Germany
5 Himeji Inst Technol, Himeji, Hyogo 67122, Japan
6 Univ Fed Parana, Dept Fis, BR-80060000 Curitiba, Parana, Brazil
RevistaSurface and Coatings Technology
Volume69
Páginas408-410
Histórico (UTC)2006-02-16 15:58:36 :: marciana -> administrator ::
2018-06-06 03:57:14 :: administrator -> marciana :: 2003
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Palavras-Chavetecnologia de plasma
plasma tecnology
plasma immersion ion implantation
titanium alloy
nitrogen implantation
three-dimensional ion implantation
nanohardness
industrial components
surface modification
ResumoPlasma immersion nitrogen implantation of Ti6Al4V (TAV) alloy was carried out to improve the surface tribological properties of test samples for artificial heart valves. Our results show that a good implantation with nitrogen peak concentration of 40% was achieved but with only approximately 50 nm implanted layer, after 60 min of treatment. Longer treatments showed no improvement in the retained dose, probably due to sputtering effects. However, both significant reduction of friction coefficient and increase in hardness was seen even for such a shallow implantation. Furthermore, the hardness improvement extended to regions much deeper than the implanted layer. Improvements of the wear resistance of such nitrogen implanted Ti alloy is expected, increasing considerably the useful lifetime of components made of TAV which is finding widespread use in biomedical and aerospace applications.
ÁreaFISPLASMA
Arranjourlib.net > Fonds > Produção anterior à 2021 > LABAP > Improvement of tribological...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Idiomaen
Arquivo Alvo62.pdf
Grupo de Usuáriosadministrator
Visibilidadeshown
Detentor da CópiaSID/SCD
Política de Arquivamentodenypublisher denyfinaldraft24
Permissão de Leituradeny from all and allow from 150.163
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/3ET2RFS
DivulgaçãoWEBSCI; PORTALCAPES.
Acervo Hospedeirosid.inpe.br/banon/2001/04.03.15.36
6. Notas
Campos Vaziosalternatejournal archivist callnumber copyright creatorhistory descriptionlevel documentstage doi e-mailaddress electronicmailaddress format isbn label lineage mark mirrorrepository nextedition notes number orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup resumeid rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url versiontype
7. Controle da descrição
e-Mail (login)marciana
atualizar 


Fechar